Container Technical Details

Container Specifications
PRODUCTION DIMENSIONS

Containers of desired sizes up to 12 meters can be produced.

METAL MATERIALS

1311 ERDEMİR GALVANIZ

BETOPAN

TSE 634-2

POLYSTRENE FOAM (EPS)

TS 7316 (DIN 4102)

EARTHQUAKE CONDITIONS

1st degree earthquake is a must.

CLIMATE CONDITIONS

3.Suitable for the climate zone

SNOW LOAD

80 Kg / m²

WIND SPEED

102 Km / Hour (Provided that it is fixed to the ground)

EXTERIOR WALL TRANSMISSION COEFFICIENT

0.48 Kcal / m2h C

ROOF TRANSMISSION COEFFICIENT

0.48 Kcal / m2h C

BASE HEAT TRANSMISSION COEFFICIENT

3.85 Kcal / m2h C

GROUND SPRING: LOAD CAP.

200 Kg / m²

BASE SYSTEM

Combined construction with a space profile bolt is used. The ground to be placed must be level.

BASE COATING

2.5 mm thick PVC Mineflo is used on 14 mm thick BETOPAN sheets (special glue).

WALL SYSTEM

Specially shaped polyurethane filled sandwich panel

WALL EXTERIOR SURFACE COATING

Outer surface coatings rall 9002 electrostatic painted 0.50 mm sheet

WALL INTERIOR SURFACE COATING

Internal surface coatings rall 9002 electrostatic painted 0.40 mm sheet

WALL INSULATION

50 mm thick, 14 kg / m³ polyurethane; It is made with full, healthy and safe materials with thermal insulation.

ROOF SYSTEM

It is a specially shaped clamped polyurethane filled sandwich panel. Rain water is evacuated by a special clamp system.

ROOF INSULATION

 50 mm Polyurethane sandwich panel

ROOF INTERIOR SURFACE COATING

 Inner surface coatings are rall 9002 electrostatic painted 0.40 mm sheet.

ROOF EXTERIOR SURFACE COATING

 Internal surface coatings are rall 9002 electrostatic painted 0.50 mm sheet metal.

EXTERIOR DOOR

Metal cased 40 mm 9002 PAINTED sandwich panel and special metal reinforcement, with sealing gasket.

INTERIOR DOOR

A MDF-lam door is mounted on an electrostatic painted galvanized metal frame. (1980X755mm)

WINDOW

A PVC window of 700 x 1100 mm is installed. It is the only wing that opens 90 degrees.

SILL

PVC moldings are used on the inner edges of the windows.

PINE

Insulating glass of 4 + 12 + 4 mm thickness is used.

EXTERIOR AND INTERIOR PAINT

RAL 9002 colored electrostatic painted sheet is used.

METAL PARTS PAINT

RAL 1019 colored electrostatic painted sheet is used.

ELECTRICAL INSTALLATION SYSTEM

Surface mounted

CABLES

3x2.5 mm NYM TSE certified cable is used for sockets and 2x1.5 mm for lighting.

LIGHTING

 First class simit armature with TSE certificate is used.

SOCKET-SWITCH

Each room has a socket and switch.

SANITARY INSTALLATION SYSTEM

SURFACE MOUNTED

SANITARY (LUMINAIRES)

First class materials with TSE certification are used.

SINK-SHOWER (ARMATURE)

ABS and Acrylic based products with TSE certification are used.

CLEAN WATER PIPES

TSE certified PPRC featured materials are used.

WASTE WATER PIPES

PVC featured materials with TSE certification are used.

SHIPMENT

Lifting is done with SPECIAL DESIGN brackets and columns.

LOCK HEIGHT 35 mm
DOOR INSULATION 20 mm STYROFOAM
DOOR HINGE 100X25mm
LIGHT CABLE 3X1.5 mm
CABLE SOCKET 3X2.5mm FLEXIBLE
MAIN LINE CABLE 3X4 mm TTR FLEXIBLE
LIGHTING INTERIOR 2X36 W FLORASAN
LIGHTING WET FLOOR LAMP 60W
OUTDOOR LIGHTING 60 W WATERPROOF
WC. LEGGED BASIN 400MMX500 mm LUX
WC 45 X 35mm Wasistas glass size sash will open inside
WC FLOOR PVC MINEFLÖ 2mm
SHOWER 700mmX700mm 800mm SHOWER TRAY
 

ADMPREFABRİK reserves the right to make changes in technical specifications without notice.